Sign In | Join Free | My burrillandco.com
Home > Protection Relay Testing >

Universal Protection Relay Testing Complying IEC61850 SV & GOOSE

Kingsine Electric Automation Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Universal Protection Relay Testing Complying IEC61850 SV & GOOSE from wholesalers
     
    Buy cheap Universal Protection Relay Testing Complying IEC61850 SV & GOOSE from wholesalers
    • Buy cheap Universal Protection Relay Testing Complying IEC61850 SV & GOOSE from wholesalers

    Universal Protection Relay Testing Complying IEC61850 SV & GOOSE

    Ask Lasest Price
    Brand Name : KINGSINE
    Model Number : K3163i
    Certification : ISO9001, CE
    Payment Terms : T/T in advance, L/C
    Supply Ability : 50 sets/month
    Delivery Time : 15 working days
    • Product Details
    • Company Profile

    Universal Protection Relay Testing Complying IEC61850 SV & GOOSE

    Universal Relay Test Set


    All-in-one Complying IEC61850 SV & GOOSE


    Product Advantage


    ◆ Digital signal complying IEC61850-9-1 / IEC61850-9-2 protocols.


    ◆ Synchronize with GPS,IRIG-B.


    ◆ Suitable testing for all kinds of electromagnetic relays,microcomputer relays.


    Ordering Ref.


    ModelCurrent OutputsVoltage Outputs
    K3166i6×35A@450VA max / 3×70A@850VA max7×310V@90VA max
    K3163i6×35A@450VA max / 3×70A@850VA max4×310V@124VA max
    K3130i3×35A@450VA max4×310V@124VA max

    Features


    All-in-one design,integrated IEC61850 SMV(Complied IEC61850-9-1,IEC61850-9-2,IEC61850-9-2LE) & GOOSE,6I+4V analog channels output,inbuilt GPS and IRIG-B,and other advanced functions.


    1. Two 100Mbit Optical Fiber ports for SMV and GOOSE simulations(exchangeable with RJ45).


    2. 6×35A & 4×310V independent high burden output channels.


    3. 13 channels independent low-level signal outputs.


    4. AC/DC measurement(8 channels inputs,class 0.05,0-600V/0-5A,auto range).


    5. Transducer calibartion (class 0.02).


    6. Energy meter calibration(Mechanical & Electronic meters).


    7. Transient play back up to 3KHZ.


    8. Light weight <18kg.


    9.Fully function KRT software testing modules.


    10.3-Years guarantee of free repair and life-long maintenance.


    11.Free software upgrade.


    Application


    Testing ItemsANSI® No.
    IEC61850 numerical IEDs relay & merge unit--
    Distance protection relay21
    Synchronising or synchronism-check relays25
    Undervoltage relays27
    Directional Power relays32
    Undercurrent or underpower relays37
    Negative sequence overcurrent relays46
    Overcurrent/ground fault relays50
    Inverse time overcurrent/ground fault relays51
    Power factor relays55
    Overvoltage relays59
    Voltage or current balance relays60
    Directional overcurrent relays67
    Directional ground fault relays67N
    DC overcurrent relays76
    Phase-angle measuring or out-of-step protection relays78
    Automatic reclosing devices79
    Frequency relays81
    Motor overload protection relays86
    Differential protection relays87
    Directional voltage relays91
    Voltage and power directional relays92
    Tripping relays94
    Voltage regulating relays--
    Overimpedance relays, Z>--
    Underimpedance relays, Z--
    Time-delay relays--

    K31 Series Characteristic


    1. 10 Channels (6×35A & 4×310V) outputs, each output channels are independent and simultaneous


    control of magnitude, phase angle and frequency values, able to inject DC, AC sine wave and up


    to 20 × harmonics.


    2. Variable battery simulator, DC 0-350V, 140Watts max.


    3. 13 Low-level channels outputs up to 8Vac/10Vdc max.


    4. 0-600V / 0-5A AC/DC measurement in 0.05 class.


    5. Graphical test modules and templates for testing of various relays.


    6. Quick relay testing facility in Manual mode.


    7. Shot/Search/Check, Point & Click testing.


    8. RIO/XRIO import & export facility.


    9. Switch on to fault test(SOTF).


    10.Power system model for dynamic testing.


    11.Inbuilt GPS and IRIG-B sync end-to-end testing.


    12.Online Vector display.


    13.Automatic test results assume.


    14.Automatic test report creation.


    15.Anti-clipping detect,wrong wiring connect alarm and self-protect, overload and overheat protection.


    Parameter


    Voltage Outputs

    Output Range & Power4×310V ac (L-N)124VA max each
    2×620V ac (L-L)248VA max each
    3×350V dc (L-N)140W max each
    AccuracyAC:<0.03%Rd + 0.02Rg Typ. / <0.07%Rd + 0.03Rg Guar.
    DC: ±10mV @<5V,±0.5% @ ≥5V
    Resolution1mV
    Distortion<0.05% Typ. / <0.1% Guar.
    Current Outputs
    Output Range & Power6×35A ac(L-N)450VA max single
    3×70A ac(2L-N)850VA max single
    1×100A ac(6L-N)1200VA max
    3×20A dc(L-N)300W max each
    AccuracyAC:<0.03%Rd + 0.02Rg Typ. / <0.15%Rd + 0.05Rg Guar.
    DC: ±5mA @<1A,±0.5% @ ≥1A
    Resolution1mA
    Distortion<0.05%Typ. / <0.1% Guar.

    Low-Level Output

    Quantity13 Channels, 16 pin aviation socket
    Voltage outputs rangeAC 0-8V, DC 0-10V
    Current outputs rangeNominal 2mA, 10mA max transient
    Output Power≥0.5VA
    Accuracy(0.01~0.8 Vrms):<0.05% Typ. / <0.1% Guar.
    (0.8~8 Vrms):<0.02% Typ. / <0.05% Guar.
    Resolution0.25mV
    Distortion(THD%)<0.05%Typ. / <0.1% Guar.

    Frequency & Phase Angle

    Frequency RangeDC~1KHZ, 3KHZ transient
    Frequency Accuracy±0.5ppm
    Frequency Resolution0.001Hz
    Phase Range0°~360°
    Phase Accuracy<0.05°Typ. / <0.1° Guar. 50/60Hz
    Phase Resolution0.001°

    IEC61850 Fiber & GOOSE Ethernet Ports (Optional Function)

    Fiber Ports

    2×100 Base-FX Full Duplex, LC type


    (Optional to 10/100Mbit, Ethernet RJ45 type)

    Fiber Type62.5/125um (Multiple optical fiber, Orange Red)
    Wavelength1310nm
    Transmit Distance>1Km
    Indicator

    Spd Green (light): Valid connection


    Link/Act Yellow (Blinking): Data exchanging

    Note: Hardware is ready, to be actived.

    Aux. DC Voltage Source(Battery simulator)

    Range0~350V @ 180W max
    Accuracy0.5%Rg Guar.

    Binary Input

    Quantity8 pairs
    Typewet/dry, measurement
    Threshold10~600Vdc or potential free, Programmable
    Time resolution100us
    Debounce time0~25ms (Software Controlled)
    Time rangeInfinite
    Time errors±1ms @ 0.001~1s, ±0.1% @>1s
    Galvanic isolation4 isolated with each 2 pairs

    Binary Output (Relay Type)

    Quantity4pairs
    TypePotential free relay contacts,software controlled
    Break Capacity ACVmax: 400Vac / Imax:8A / Pmax:2500VA
    Break Capacity DCVmax: 300Vdc / Imax:5A / Pmax:150W

    Binary Output (Semiconductor Type)

    Quantity4pairs
    TypeOpen-collector, 14 pin Aviation socket
    Break Capacity DC

    5~15Vdc / 5mA, 10mA max


    AC not permit

    Response time100us

    Synchronization

    Synchronization Mode GPS, SMA type antenna connector / IRIG-B / IEEE1588

    Power supply & Environment

    Nominal Input Voltage100~240Vac
    Permissible Input Voltage85~264Vac, 125~350VDC
    Nominal Frequency50/60Hz
    Permissible Frequency45Hz~65Hz
    Power Consumption1500 VA max
    Connection TypeStandard AC socket 60320
    Operating Temperature-10℃~55℃
    Storage Temperature-20℃~70℃
    Humidity<95%RH, non-condensing

    Others

    PC ConnectionRJ45 Ethernet, 10/100M
    Grounding Terminal4mm banana socket
    Weight18Kg
    Dimensions(W×D×H)468×375×164(mm)

    Optional Modules


    DC Measurement Input(Transducer calibrator) * Hardware is ready,to be actived.

    Voltage inputRange0~±10V dc
    Max Input±11V dc
    Accuracy<0.02% rg Typ. / <0.05% rg Guar.
    Input Impedance1M ohm
    Current InputRange0~±1mA / 1~20mA, auto range
    Max Input600mA
    Accuracy<0.02% rg Typ. / <0.05% rg Guar.
    Input Impedance15 ohm

    AC / DC Measurement Input( Standard meter ) * Require extra PCB installed in factory only

    Input Quantity8 channels (blend with binary input pairs)
    Voltage rang0~600Vrms (Rg: 0.1V,1V,10V,60V,600V)
    Voltage accuracy<0.05% Rg
    Current rangeShunt input: 0~5Arms / 0~30Arms (Optional)
    Current accuracy<0.1% Rg
    Sample rate10KHz
    Input impedance600KΩ
    Frequency range45~65Hz, Accuracy<0.01Hz
    Phase accuracy0~360°,<0.2° Typ.

    Energy Meter Calibration * Hardware is ready,to be actived

    Sensor UsageMechanical meters / Electronic meters
    Sensor OutputHigh level : >4.5V, Low level: <0.2V
    Pulse Input1 pulse input port
    Pulse Range500KHz pulse input Max.
    Pulse Output1 Transistor output, Open-collector, 5-15Vdc/5mA