Sign In | Join Free | My burrillandco.com
Home > Multifunctional Power Meter >

PMC72S 3 Phase Multi Function Digital Meter Power Monitoring Meter

Kingsine Electric Automation Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap PMC72S 3 Phase Multi Function Digital Meter Power Monitoring Meter from wholesalers
     
    Buy cheap PMC72S 3 Phase Multi Function Digital Meter Power Monitoring Meter from wholesalers
    • Buy cheap PMC72S 3 Phase Multi Function Digital Meter Power Monitoring Meter from wholesalers

    PMC72S 3 Phase Multi Function Digital Meter Power Monitoring Meter

    Ask Lasest Price
    Brand Name : KINGSINE
    Model Number : PMC72S
    Certification : CE/ISO9001
    Price : negotiation
    Payment Terms : L/C, T/T
    • Product Details
    • Company Profile

    PMC72S 3 Phase Multi Function Digital Meter Power Monitoring Meter

    PMC72S meter is a multi-functional power monitoring meter, it combines function of collecting data and control, and it can replace many kind of meters, relays, transformers and others components. PMC72S can be installed in different positions of electricity distribution system.


    PMC72S is a true RMS-based measuring meter that can accurately measure highly nonlinear loads. Its advanced grid frequency synchronization sampling technology enables it to accurately measure a variety of power parameters, including voltage/current RMS, frequency, active power, reactive power, apparent power, power factor, input/output active energy, total active energy, Input/output reactive power, total reactive power, apparent power, voltage total harmonic distortion (THD), 1~31 voltage harmonics, current total harmonic distortion (THD) and 1~31 current harmonics, etc. . All measurement values, min value and max value, and demand measurement values can be viewed on the screen display or be checked via remotely software control.

    Overview of Meter functions

    Table 1

    Host Devices functions and characteristics
    Transient true RMS value
    Current Each single phase and combined phase, average value
    Phase voltage/Line voltage Each single phase and combined phase, average value
    Frequency 45~65Hz
    Max/Min VALUE
    Max/Min CURRENT RMS
    Max/MinVOLTAGE RMS
    Max/Min Frequency
    Max/Min THD I and THD U
    Demand and peak value
    Current per phase the present value/peak value/monthly peak value
    Power quality
    (THD) current and voltage
    1-31times harmonic analysis current and voltage
    Voltage crest factor CF and current K factor
    Event record
    100pcs SOE event record
    Alarm system
    8 warning channels with configurable limit value
    4 warning channels with configurable logic
    Communication
    RS-485 /MODBUS-RTU Protocol
    Display
    Large screen STN liquid display
    Real time clock
    Year, month, date, minute, second
    Others
    Support program online upgrade

    Table 2

    Auxiliary module features
    DI input module (optional)
    2-channel DI input (Dry Contact)
    Relay (DO) output module (optional)
    1-channel relay output, which can be set by local over-limit alarm or by remote control
    Analog input (AI)/output (AO) module (optional)
    1 Channel only
    Being optional for 4-20mA DC analog input, 0-5V DC analog input, 4-20mA DC analog output

    Technical Parameters:

    Electrical characteristics
    Measure Type3P3W ACsystem,3P4W ACsystem
    Sampling rate128 points per cycle
    Data refresh rate1S
    Measure accuracyCurrent±0.2%FS
    Voltage±0.2%FS
    Power0.5S
    Frequency±0.001Hz
    DC input
    (AI)
    0.5% FS
    DC output
    (AO)
    0.5% FS
    Input voltage characteristicsMeasure
    Voltage
    3 *220/380V(Directly input)
    3 * 57.7/100V(PT secondary side)
    Allowed overload capability1.2 times/continuous
    Input resistance300KΩ/phase
    Input current
    characteristics
    Measure
    current
    5A (CT Secondary side)Or 1A (CT Secondary side)
    Allowed
    Overload
    capability
    1.2 times/continuous
    Input resistance<0.1Ω
    Binary inputWorking valtage15 VDC
    Input
    resistance
    12KΩ
    Isolation
    valtage
    2KV
    Relay OutputNode typeMechanical contact
    Node capability220 VAC/5A,30 VDC/5A
    4-20mA
    DC input
    measurement
    Measure current4-20mA
    Allowed
    Overload
    capability
    1.2 times/continuous
    Input resistance10Ω
    Isolation
    voltage
    2KV
    0-5V
    DC input
    measurement
    Measure
    voltage
    0-5V
    Allowed
    Overload
    capability
    1.2 times/continuous
    Input resistance12.5KΩ
    Isolation
    voltage
    2KV
    4-20mA
    DC output
    Open-circuit15VDC
    Load capability600Ω
    Isolation
    voltage
    2KV
    Power supplyAC85~264 VAC/45-65Hz
    DC100~375 VDC
    Power consumption< 3W
    Mechanical performance
    weight<0.5kg
    IP protection LevelMeter Panel IP52
    Meter Host IP30
    DimensionHost75 X 75 X 113 mm
    Working
    temperature
    Display screen-20~70
    Meter-25~70
    Storage
    temperature
    Meter+display screen-40~85
    Relative humidity5% - 90%RH,No condensation
    EMC
    Antistatic
    discharge interference
    IEC 61000-4-2,Level 4
    Anti-fast
    transient group pulse
    IEC 61000-4-4,Level 4
    Anti-surgIEC 61000-4-5,Level 3
    Resistance to power frequency magnetic fieldIEC 61000-4-8,Level 3
    Electrical insulation performance
    Insulation resistenceGB/T13729,>50MΩ
    Power frequency withstandGB/T13729,AC 3KV 50Hz /1min
    Impulse voltageGB/T13729,5KV,1.2/50us

    PMC72S Guide for selection of power parameter measurement and control instrument

    Model specification:PMC72S-----
    Model code:
    157.7/100V Rated measurement voltage,5A Rated measurement current.
    257.7/100V Rated measurement voltage,1A Rated measurement current.
    3220/380V Rated measurement voltage,5A Rated measurement current.
    4220/380V Rated measurement voltage,1A Rated measurement current.
    Model code:
    1Power supply:85~264 VAC/45-65Hz,100~300 VDC
    Model code:
    0Without DI
    22 Channels DI
    Model code:
    0Without relay output
    1Optional 1 Channel relay output
    Model code:
    abab is a 2 integer,a means AI01 port optional for AI/AO modules,b means AI02 port optional for AI/AO
    0none
    1 -0-5VDCanaloginputmeasure(AI)
    2 -4-20mA DC analog input measure(AI)
    3 -4-20mA DC analog output(AO)For example:ab=00,Means AI01 port is not equipped with AI/AO module,AI02 port is not equipped with AI/AOmodule
    ab =01,Means options 0-5V DC analog input measure;

    For example:Order model:PMC72S-3-1-2-1-02
    Means PMC72S rated measure 220/380V,5Aworking power supply as 85~264 VAC/45-65Hzoptional with 2channels binary input(DI)1channels relay output1channel 4-20mA DC analog input measure (AI01 port),1 channel 4-20mA DC analog input measure(AI02 port)

    Quality PMC72S 3 Phase Multi Function Digital Meter Power Monitoring Meter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Kingsine Electric Automation Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)